24 research outputs found

    Implantation of paclitaxel-eluting stents in saphenous vein grafts: clinical and angiographic follow-up results from a multicentre study.

    Get PDF
    Objective: To define the clinical and angiographic follow-up results after implantation of paclitaxel-eluting stents (PESs) in stenotic saphenous vein grafts (SVGs). Design: Prospective multicentre study. Comparison with a control group. Methods: 60 consecutive patients with 65 lesions located in 65 SVGs (mean (SD) age of vein grafts 11.3 (5.7) years) treated with PES (V-Flex Plus, 2.7 mg/mm2 paclitaxel, Cook) and 60 patients with 60 SVG lesions treated with bare metal stent (BMS) were included. Lesions had to be ,20 mm in length and in grafts of 2.75–3.5 mm diameter. The 6 month angiographic follow-up was obtained on 51 lesions (79%) of the PES group and on 51 lesions (85%) of the BMS group. Results: Baseline clinical and angiographic characteristics were comparable between both groups. At angiographic follow-up, three vein grafts in the PES group and five vein grafts in the BMS group were occluded. In-stent late lumen loss was lower in PES than in BMS (0.61 (0.81) vs 1.06 (0.72) mm, respectively; p = 0.021). In-stent binary restenosis rates were 12% vs 33%, respectively, (p = 0.012). Linear regression analysis showed BMS to be the only factor with an effect on late lumen loss (p = 0.011). Target-vessel failure rates were 18% in the PES group and 41% in the BMS group (p = 0.019), whereas major adverse cardiac event (MACE) rates at 180 days were 15% and 37%, respectively (p = 0.014). Conclusions: Implantation of non-polymer-based PES in SVG lesions is associated with a lower late lumen loss and restenosis rate than those of BMS. There remains a substantial target-vessel failure rate and MACE rate even at 6 months owing to graft occlusion or new lesions in the graft

    Transcutaneous aortic valve replacement with the Edwards SAPIEN XT and Medtronic CoreValve prosthesis under fluoroscopic guidance and local anaesthesia only

    Get PDF
    Objective: To assess the feasibility of transcatheter aortic valve implantation (TAVI; Medtronic CoreValve and Edwards SAPIEN XT) under local anaesthesia with only mild analgesic medication and fluoroscopic guidance. Methods: 461 patients underwent TAVI under local anaesthesia with lidocaine. The procedure was performed successfully in 459 of the cases. All patients were also treated with piritramide, metoclopramide hydrochloride and 62 mg dimenhydrinate. Monitoring consisted of a six-electrode, virtual 12-lead ECG, pulse oximetry, and invasive arterial pressure measurement. There was no continuous surveillance by an anaesthesiologist. Results: There was no need for conversion to general anaesthesia except in four patients who required cardiopulmonary resuscitation. Conscious sedation with intravenous administration of midazolam for agitation or inotropic medication for prolonged hypotension was necessary in only seven of the 461 patients. The combined safety end point according to the Valve Academic Research Consortium consensus document was reached in 12.6%. Conclusions: Our results show that TAVI performed under local anaesthesia with only mild analgesic medication and under fluoroscopic guidance is feasible, with good outcome comparable to published data

    Ethnic Identification and Stereotypes in Western Europe, circa 1100-1300

    Full text link

    Exercise-induced human coronary collateral function: quantitative assessment during acute coronary occlusions.

    No full text
    In 50 patients undergoing percutaneous transluminal coronary angioplasty because of chronic angina pectoris, a collateral flow index (CFI) was determined at the start and the end of two 1-min coronary occlusions, randomly accompanied by a resting state or a 3-min dynamic handgrip exercise (DHE). CFI expressing collateral flow relative to normal antegrade flow was determined by simultaneous coronary occlusive pressure, mean aortic pressure and central venous pressure measurements. When comparing CFI without and with DHE at the start as well as at the end of balloon occlusions, a significant increase was observed with DHE (overall p < 0.0001); start: 0.18 +/- 0.12 vs. 0.22 +/- 0.13, respectively (p = 0.01); end of occlusion: 0.21 +/- 0.14 vs. 0.25 +/- 0.14, respectively (p = 0.007)